Azure Local - Fully Converged Physical Network Design Reference

This document provides a comprehensive reference for implementing a fully converged physical network design for Azure Local deployments. It includes configuration examples, validation procedures, and best practices for customers and partners deploying Azure Local in production environments.

Executive Summary

Azure Local's fully converged network design provides a unified approach to handling management, compute, and storage traffic over the same physical infrastructure. This design pattern offers:

  • Simplified Infrastructure: Reduced hardware footprint and cabling complexity
  • Cost Optimization: Efficient use of network resources and equipment
  • Scalability: Support for 2 to 16 nodes with consistent configuration patterns

Design Overview

The fully converged physical network architecture integrates management, compute, and storage traffic over the same physical Ethernet interfaces. This design minimizes hardware footprint while maximizing scalability and deployment simplicity.

Key Design Principle: In Fully Converged deployments, the recommended baseline design uses one storage VLAN per ToR switch: Storage VLAN A is configured only on ToR-A and mapped to one physical NIC, while Storage VLAN B is configured only on ToR-B and mapped to the other physical NIC. In failure scenarios (NIC or ToR), SMB/RDMA traffic automatically fails over to the remaining path with reduced bandwidth but no functional impact. Configuring both storage VLANs on both ToR switches is also supported but optional.

Architecture Components

This section describes the essential components required for implementing a fully converged Azure Local network design.

Top-of-Rack (ToR) Switches

Physical switches that provide redundant Layer 2/Layer 3 connectivity for the Azure Local cluster. Key characteristics:

  • Each Azure Local node connects to two separate ToR switches for high availability
  • All switch ports must be configured as IEEE 802.1Q trunk ports to support multiple VLANs
  • Supports standard data center switch features including MLAG, BGP routing, and QoS policies

Azure Local Nodes

Physical hosts running the Azure Local operating system. In a fully converged design:

  • Each node requires minimum two high-speed physical NICs (10Gbps or higher)
  • NICs must support RDMA (Remote Direct Memory Access) for optimal storage performance
  • All traffic types (management, compute, and storage) flow over the same physical interfaces using VLAN segmentation

Network ATC (Automatic Network Configuration)

Azure Local's intent-based networking framework that simplifies network deployment:

  • Defines and deploys logical networking configurations through "intents"
  • In fully converged deployments, uses a single Management + Compute + Storage intent
  • Automatically configures VLANs, IP addressing, and adapter settings across the cluster

Switch Embedded Teaming (SET)

Windows-native NIC teaming technology that provides link-level redundancy:

  • Creates a single logical interface from multiple physical NICs
  • Operates in switch-independent mode for maximum compatibility
  • Only supported virtual switch technology on Azure Local
  • Provides load balancing and failover capabilities

Physical Network Topology

This section demonstrates a fully converged Azure Local deployment where management, compute, and storage traffic all share the same NICs using VLAN segmentation. The design scales seamlessly from 2 to 16 nodes with consistent configuration patterns.

Design Characteristics

  • Fully Converged: All traffic types (Management, Compute, Storage) utilize the same physical links
  • Redundant Infrastructure: Each node connects to both ToR1 and ToR2 for high availability
  • Switch Embedded Teaming: Host-level NIC bonding provides fault tolerance and load balancing
  • VLAN Segmentation: Traffic isolation using IEEE 802.1Q VLAN tagging

Topology Diagram

AzureLocalPhysicalNetworkDiagram_FullyConverged

Cabling Configuration Example

The following tables demonstrate physical connectivity between Azure Local nodes and Top-of-Rack switches in a three-node cluster. This pattern scales consistently for larger deployments.

Cabling Requirements:

  • Each node requires two network connections (NIC A and NIC B)
  • Each NIC connects to a different ToR switch to ensure redundancy
  • Use identical cable types and speeds for consistent performance

Host 1

Azure Local Node Interface ToR Switch Interface
Host1 NIC A ToR1 Ethernet1/1
Host1 NIC B ToR2 Ethernet1/1

Host 2

Azure Local Node Interface ToR Switch Interface
Host2 NIC A ToR1 Ethernet1/2
Host2 NIC B ToR2 Ethernet1/2

Host 3

Azure Local Node Interface ToR Switch Interface
Host3 NIC A ToR1 Ethernet1/3
Host3 NIC B ToR2 Ethernet1/3

VLAN Architecture

The fully converged design uses VLAN segmentation to isolate different traffic types while sharing the same physical infrastructure.

Traffic Type Purpose VLAN ID Configuration Notes
Management Cluster and host management traffic 7 Native VLAN, L3 routed (SVI)
Compute Virtual machine workload traffic 201 Tagged VLAN, L3 routed (SVI)
Storage 1 SMB storage over RDMA (first path) 711 Tagged VLAN, L2 only (no SVI)
Storage 2 SMB storage over RDMA (second path) 712 Tagged VLAN, L2 only (no SVI)

Note

Storage VLAN Design Pattern for Fully Converged: The recommended baseline design uses one storage VLAN per ToR switch:

  • Storage VLAN 711 is configured only on ToR-A and mapped to one physical NIC
  • Storage VLAN 712 is configured only on ToR-B and mapped to the other physical NIC
  • In failure scenarios (NIC or ToR), SMB/RDMA traffic automatically fails over to the remaining path

Configuring both storage VLANs on both ToR switches is also supported but optional. Testing has confirmed no meaningful resiliency benefit from this configuration.

Top-of-Rack Switch Configuration

This design utilizes two physical switches as Top-of-Rack (ToR) devices to provide redundant uplink connectivity for all Azure Local nodes.

Switch Requirements:

  • Support for IEEE 802.1Q VLAN tagging and trunking
  • Layer 3 routing capabilities (SVI interfaces)
  • RDMA/RoCE support with Data Center Bridging (DCB)
  • Quality of Service (QoS) policy enforcement
  • Optional: Multi-Chassis Link Aggregation (MLAG) support

Redundancy Design:

  • ToR switches may be configured with MLAG (Multi-Chassis Link Aggregation) for enhanced redundancy
  • MLAG configuration is optional, as redundancy is primarily achieved through host-side SET (Switch Embedded Teaming)
  • Core network layer connectivity (routers, firewalls) is considered out of scope for this document

Interface & VLAN Configuration

This section provides configuration guidance using Cisco Nexus 93180YC-FX3 (NX-OS 10.x) as the reference platform. The principles apply to other vendor switches with appropriate syntax modifications.

VLAN Configuration Summary:

  • VLAN 7 (Management): Layer 3 routed VLAN, configured as native VLAN on trunk ports
  • VLAN 201 (Compute): Layer 3 routed VLAN, tagged on trunk ports
  • VLAN 711 (Storage 1): Layer 2 only VLAN (no SVI), tagged on trunk ports for RDMA traffic
  • VLAN 712 (Storage 2): Layer 2 only VLAN (no SVI), tagged on trunk ports for RDMA traffic

Note

In Fully Converged deployments, the recommended design uses one storage VLAN per ToR switch: Storage VLAN 711 on ToR-A only, Storage VLAN 712 on ToR-B only. This simplifies configuration while automatic failover handles NIC or ToR failures.

Important

Storage VLANs 711 and 712 should NOT be permitted on the ToR-to-ToR peer-link (vPC peer-link, MLAG inter-switch trunk, or any L2 interconnect between ToR switches). Storage traffic must flow directly from host to ToR to destination host to maintain optimal RDMA performance. Allowing storage VLANs on peer links can cause performance degradation.

Key Configuration Requirements:

  • Enable Priority Flow Control (PFC) for RDMA support
  • Configure jumbo frames (MTU 9216) for optimal performance
  • Apply QoS service policies for traffic prioritization
  • Set appropriate spanning-tree settings for edge ports
Sample NX-OS Configuration

ToR1 Configuration:

vlan 7
  name Management_7
vlan 201
  name Compute_201
vlan 711
  name Storage_711

interface Vlan7
  description Management
  no shutdown
  mtu 9216
  ip address 10.101.176.2/24
  hsrp 7
    ip 100.101.176.1

interface Vlan201
  description Compute
  no shutdown
  mtu 9216
  ip address 10.101.177.2/24
  hsrp 201
    ip 100.101.177.1

interface Ethernet1/1-3
  description To_Azure_Local_Host_FullyConverged
  switchport
  switchport mode trunk
  switchport trunk native vlan 7
  switchport trunk allowed vlan 7,201,711
  priority-flow-control mode on send-tlv
  spanning-tree port type edge trunk
  mtu 9216
  service-policy type qos input AZS_SERVICES
  no shutdown

ToR2 Configuration:

vlan 7
  name Management_7
vlan 201
  name Compute_201
vlan 712
  name Storage_712

interface Vlan7
  description Management
  no shutdown
  mtu 9216
  ip address 10.101.176.3/24
  hsrp 7
    ip 100.101.176.1

interface Vlan201
  description Compute
  no shutdown
  mtu 9216
  ip address 10.101.177.3/24
  hsrp 201
    ip 100.101.177.1

interface Ethernet1/1-3
  description To_Azure_Local_Host_FullyConverged
  switchport
  switchport mode trunk
  switchport trunk native vlan 7
  switchport trunk allowed vlan 7,201,712
  priority-flow-control mode on send-tlv
  spanning-tree port type edge trunk
  mtu 9216
  service-policy type qos input AZS_SERVICES
  no shutdown

Note

  • ToR-A has Storage VLAN 711 only, ToR-B has Storage VLAN 712 only (one storage VLAN per ToR)
  • In failure scenarios, SMB/RDMA traffic automatically fails over to the remaining path
  • QoS policies and routing design (e.g., uplinks, BGP/OSPF, default gateway) will be introduced in a separate document

Configuration Validation

This section provides comprehensive validation procedures to verify the network configuration is functioning correctly in already deployed Azure Local environments. These validation commands are intended for troubleshooting and verifying existing production deployments, not for fresh installations.

Azure Local Host Validation

Use these PowerShell commands on deployed Azure Local nodes to validate network adapter configuration and RDMA connectivity:

1. Verify Network Adapter Configuration

# Display network adapters and VLAN assignments
Get-NetAdapter | Format-Table InterfaceAlias, VlanID, MacAddress -AutoSize

# Check VLAN isolation settings for virtual adapters
Get-VMNetworkAdapterIsolation -ManagementOS | Format-Table ParentAdapter, IsolationMode, DefaultIsolationID -AutoSize

2. Validate SMB Multichannel and RDMA Connectivity

[Host3]: PS C:\Users\Administrator\Documents> Get-NetAdapter | ft InterfaceAlias, VlanID, MacAddress

InterfaceAlias                     VlanID MacAddress       
--------------                     ------ ----------       
ethernet                                0 0C-42-A1-F9-69-4A
vSMB(managementcompute#ethernet 2)        00-15-5D-C8-20-07
ethernet 2                              0 0C-42-A1-F9-69-4B
vManagement(managementcompute)            0C-42-A1-F9-69-4A
vSMB(managementcompute#ethernet)          00-15-5D-C8-20-06

[Host3]: PS C:\Users\Administrator\Documents> Get-VMNetworkAdapterIsolation -ManagementOS | ft ParentAdapter, IsolationMode, DefaultIsolationID

ParentAdapter                                                         IsolationMode DefaultIsolationID
-------------                                                         ------------- ------------------
VMInternalNetworkAdapter, Name = 'vSMB(managementcompute#ethernet)'            Vlan                711
VMInternalNetworkAdapter, Name = 'vManagement(managementcompute)'              Vlan                  0
VMInternalNetworkAdapter, Name = 'vSMB(managementcompute#ethernet 2)'          Vlan                712



# Verify SMB Multichannel connections and RDMA usage
[Host3]: PS C:\Users\Administrator\Documents> Get-SmbMultichannelConnection | Format-Table ClientInterfaceFriendlyName, ClientIpAddress, ServerIpAddress, ClientRdmaCapable, RdmaConnectionCount, TcpConnectionCount -AutoSize

ClientInterfaceFriendlyName         ClientIpAddress ServerIpAddress ClientRdmaCapable RdmaConnectionCount TcpConnectionCount
---------------------------         --------------- --------------- ----------------- ------------------- ------------------
vSMB(managementcompute#ethernet 2)  10.71.2.10      10.71.2.34      True              2                   0
vSMB(managementcompute#ethernet)    10.71.1.249     10.71.1.214     True              2                   0

# Verify SMB connections
[Host3]: PS C:\Users\Administrator\Documents> Get-SmbConnection

ServerName ShareName UserName      Credential    Dialect NumOpens
---------- --------- --------      ----------    ------- --------
Host4      c$        Administrator Administrator 3.1.1   2

Note

SMB Multichannel Validation Key Points:

  • Storage VLANs 711 and 712 are operational with RDMA enabled (each mapped to its respective ToR)
  • RdmaConnectionCount = 2 confirms RDMA is being used for storage traffic
  • TcpConnectionCount = 0 shows no fallback to regular TCP
  • SMB 3.1.1 dialect is being used for optimal performance
  • This validates that storage traffic is using RDMA as intended
Switch Validation

Verify Top-of-Rack switch configuration and MAC address learning to ensure proper connectivity.

Note

With Switch Embedded Teaming (SET), storage VLAN traffic load balancing is dynamic. MAC addresses for VLANs 711 and 712 may appear on different ToR switches or ports depending on active traffic patterns and SET's load distribution. You may need to generate storage traffic to observe MAC learning.

Step 1: Verify VLAN Configuration

Confirm that storage VLANs 711 and 712 are allowed on the trunk to the host:

# Verify VLANs are allowed on the interface trunk
ToR1# show interface ethernet 1/3 trunk

Port          Native  Status        Port
              Vlan                  Channel
---------------------------------------------------------------------------
Eth1/3        1       trunking      --

Port          Vlans Allowed on Trunk
---------------------------------------------------------------------------
Eth1/3        1,7,711-712

Step 2: Verify MAC Address Learning

Check MAC address table entries for storage VLANs. The example below shows one possible state - actual results will vary based on active traffic and SET load balancing decisions:

# Check per-VLAN MAC table entries across the ToR
ToR1# show mac address-table vlan 711
Legend:
        * - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay MAC
        age - seconds since last seen,+ - primary entry using vPC Peer-Link,
        (T) - True, (F) - False, C - ControlPlane MAC, ~ - vsan
   VLAN     MAC Address      Type      age     Secure NTFY Ports
---------+-----------------+--------+---------+------+----+------------------
*  711     0015.5dc8.2006   dynamic  0         F      F    Eth1/3

ToR1# show mac address-table vlan 712
Legend:
        * - primary entry, G - Gateway MAC, (R) - Routed MAC, O - Overlay MAC
        age - seconds since last seen,+ - primary entry using vPC Peer-Link,
        (T) - True, (F) - False, C - ControlPlane MAC, ~ - vsan
   VLAN     MAC Address      Type      age     Secure NTFY Ports
---------+-----------------+--------+---------+------+----+------------------
*  712     0015.5dc8.2007   dynamic  0         F      F    Eth1/3

Expected Results:

  • VLANs 711 and 712 must be allowed on the trunk interface
  • MAC addresses for storage VLANs should be learned on the ToR switches when storage traffic is active
  • Due to SET load balancing, MAC addresses may appear on either ToR switch and on different ports depending on traffic distribution
  • If no MACs are visible for a VLAN, generate storage traffic (e.g., copy files between cluster nodes) and recheck

Quality of Service (QoS)

Quality of Service configuration is essential for optimal Azure Local performance. For detailed QoS policy configuration:

Reference: Quality of Service (QoS) Policy

BGP Routing

For BGP routing configuration and best practices in Azure Local deployments:

Reference: Azure Local BGP Routing

Frequently Asked Questions

Q: How should Storage VLANs be configured in Fully Converged deployments?

A: The recommended baseline design uses one storage VLAN per ToR switch for Fully Converged deployments:

  • Storage VLAN A (711) is configured only on ToR-A and mapped to one physical NIC
  • Storage VLAN B (712) is configured only on ToR-B and mapped to the other physical NIC
  • In failure scenarios (NIC or ToR failure), SMB/RDMA traffic automatically fails over to the remaining path with reduced bandwidth but no functional impact

Storage VLAN Configuration:

Deployment Pattern Storage NICs ToR VLAN Config Why
Fully Converged Shared (2 NICs total) S1 on ToR-A only, S2 on ToR-B only One storage VLAN per NIC; failover occurs automatically
Switched Dedicated (4 NICs total) S1 on ToR-A only, S2 on ToR-B only Each storage NIC connects to a specific ToR

Note

Configuring both storage VLANs on both ToR switches is also supported but optional. Testing has confirmed there is no meaningful resiliency or failover benefit from this configuration, and it increases complexity without improving availability.

Additional Resources

For comprehensive Azure Local networking information, refer to these official Microsoft documentation resources:

Official Documentation

Technical Deep Dives