Decision Explainability

Overview

The logic engine produces human-readable explanations alongside its control output. These are surfaced via the MCP get_decision_explanation tool and stored in CalculationOutput.explanation.

Data Flow

DefaultLogic.calculate()
    → self._explain("Current price: 0.1500, Battery: 5000 Wh stored, ...")
    → __is_discharge_allowed()
        → self._explain("Battery above always-allow-discharge limit ...")
        OR
        → self._explain("Usable energy (4500 Wh) <= reserved energy (5000 Wh) ...")
    → self._explain("Decision: Allow discharge")
    → stored in CalculationOutput.explanation: List[str]

core.py stores last_logic_instance
    → api_get_decision_explanation() reads explanation from it

MCP get_decision_explanation tool
    → returns {mode, mode_name, explanation_steps[], override_active}

Explanation Points

The following decision points produce explanation messages:

Location Explanation
calculate_inverter_mode entry Current price, battery state summary
is_discharge_always_allowed Above/below always-allow-discharge limit
Discharge surplus check Usable energy vs reserved energy comparison
Reserved slots Number of higher-price slots reserved for
Grid charging possible SOC vs charging limit check
Required recharge energy How much grid energy needed
Final decision "Allow discharge" / "Force charge at X W" / "Avoid discharge"

Lifecycle

  • Explanation list is reset every evaluation cycle (new CalculationOutput())
  • Between cycles, api_get_decision_explanation() returns the last completed evaluation
  • No accumulation across cycles, no staleness

Files Modified

File Change
logic/logic_interface.py Added explanation: List[str] to CalculationOutput
logic/default.py Added _explain() method, annotation calls throughout logic
core.py Added api_get_decision_explanation() getter

Example Output

{
  "mode": 10,
  "mode_name": "Allow Discharge",
  "explanation_steps": [
    "Current price: 0.1500, Battery: 5000 Wh stored, 4500 Wh usable, 5000 Wh free capacity",
    "Usable energy (4500 Wh) > reserved energy (2000 Wh) — surplus available for discharge",
    "Decision: Allow discharge"
  ],
  "override_active": false
}