GreenOps Methodology Ledger v2.0.0

Methodology transparency is the only defence against greenwashing.

All maths in GreenOps is open, auditable, and reproducible from factors.json. This document defines the exact formulas, assumptions, and data sources used in every calculation.


Cloud Provider Coverage

Provider Regions Instances Status
AWS 14 40 ✅ Full coverage
Azure 17 16 ✅ Full coverage
GCP 15 15 ✅ Full coverage

Run greenops-cli --coverage to see the full instance and region list per provider.


Emission Scopes Covered

Scope What it measures GreenOps status
Scope 2 — Operational CPU power draw × grid carbon intensity ✅ Tracked
Scope 3 — Embodied Hardware manufacturing lifecycle ✅ Tracked
Water consumption Data centre cooling water withdrawal ✅ Tracked
Scope 3 — Supply chain Software, logistics, employee travel ❌ Out of scope
Scope 1 — Direct On-site combustion ❌ Not applicable (cloud)

Scope 2: Operational Emissions

Power Model

GreenOps uses the linear interpolation model from the Cloud Carbon Footprint (CCF) methodology, extended with memory power draw:

W_cpu    = W_idle + (W_max - W_idle) × utilization
W_memory = memory_gb × 0.392 W/GB
W_effective = W_cpu + W_memory

Where:

  • W_idle = idle TDP (watts) from factors.json
  • W_max = maximum TDP (watts) from factors.json
  • utilization = CPU utilisation fraction (default: 0.50, matching CCF baseline)
  • memory_gb = RAM size from factors.json
  • 0.392 W/GB = CCF memory power coefficient (constant, not utilization-dependent)

Memory power draw is constant regardless of CPU utilisation. This reflects that DRAM draws near-constant power whether or not it is actively being written to, consistent with CCF v3 methodology.

Carbon Calculation

energy_kwh = W_effective × PUE × hours_per_month / 1000
co2e_grams = energy_kwh × grid_intensity_gco2e_per_kwh

PUE by Provider

Provider PUE Source
AWS 1.13 AWS sustainability reports
Azure 1.125 Microsoft sustainability reports
GCP 1.10 Google sustainability reports

GCP's 1.10 PUE is the best in class among the three major providers, producing ~3% less overhead energy per unit of compute.

Worked Example — AWS m5.large in us-east-1 at 50% utilisation

  1. CPU power: W_cpu = 6.8 + (20.4 - 6.8) × 0.50 = 13.6W
  2. Memory power: W_mem = 8GB × 0.392 = 3.136W
  3. Total: W = 13.6 + 3.136 = 16.736W
  4. Energy: 16.736W × 1.13 PUE × 730h / 1000 = 13.816 kWh/month
  5. Carbon: 13.816 × 384.5 = 5,308.2g CO2e/month

Worked Example — Azure Standard_D2s_v3 in eastus at 50% utilisation

  1. CPU power: W_cpu = 6.8 + (20.4 - 6.8) × 0.50 = 13.6W
  2. Memory power: W_mem = 8GB × 0.392 = 3.136W
  3. Total: W = 16.736W
  4. Energy: 16.736W × 1.125 PUE × 730h / 1000 = 13.745 kWh/month
  5. Carbon: 13.745 × 380.0 = 5,222.9g CO2e/month

Worked Example — GCP n2-standard-2 in us-central1 at 50% utilisation

  1. CPU power: W_cpu = 6.8 + (20.4 - 6.8) × 0.50 = 13.6W
  2. Memory power: W_mem = 8GB × 0.392 = 3.136W
  3. Total: W = 16.736W
  4. Energy: 16.736W × 1.10 PUE × 730h / 1000 = 13.445 kWh/month
  5. Carbon: 13.445 × 340.0 = 4,569.3g CO2e/month

Scope 3: Embodied Emissions

Embodied carbon covers the manufacturing, transport, and end-of-life disposal of server hardware — prorated to the fraction of a physical server this instance type occupies.

Formula

embodied_gco2e_per_month = (server_total_embodied_gco2e / lifespan_hours / vcpus_per_server)
                           × vcpus × 730h × architecture_factor

Constants

Parameter Value Source
Server total embodied CO2e 1,200,000 gCO2e CCF DELL R740 baseline
Server lifespan 4 years = 35,040 hours AWS/CCF assumption
vCPUs per physical server 48 Dual-socket Xeon baseline
ARM architecture discount 0.80 (20% lower) Graviton/Ampere smaller die + lower TDP

Per-vCPU rates

x86_64: (1,200,000 / 35,040 / 48) × 730 = 520.8g CO2e/vCPU/month
arm64:  520.8 × 0.80                     = 416.7g CO2e/vCPU/month

The ARM discount applies equally to AWS Graviton, Azure Ampere (Dps-series), and GCP T2A instances — all use Arm Neoverse cores with comparable manufacturing profiles.


Water Consumption

energy_kwh_IT = W_effective × hours / 1000   (IT load, before PUE)
water_litres   = energy_kwh_IT × WUE_litres_per_kwh

WUE is applied to IT load (before PUE multiplication), matching the AWS/Azure/Google definition.

Regional WUE Values

AWS regions

Region Location WUE (L/kWh)
us-east-1 N. Virginia 0.46
us-east-2 Ohio 0.52
us-west-1 N. California 0.38
us-west-2 Oregon 0.18
eu-west-1 Ireland 0.22
eu-west-2 London 0.25
eu-central-1 Frankfurt 0.28
eu-north-1 Stockholm 0.10
ap-southeast-1 Singapore 0.58
ap-southeast-2 Sydney 0.45
ap-northeast-1 Tokyo 0.50
ap-south-1 Mumbai 0.72
ca-central-1 Canada 0.20
sa-east-1 São Paulo 0.35

Azure regions

Region Location WUE (L/kWh)
swedencentral Sweden Central 0.10
westus2 West US 2 0.18
northeurope Ireland 0.22
canadacentral Canada Central 0.20
westeurope Netherlands 0.20
uksouth London 0.25

GCP regions

Region Location WUE (L/kWh)
europe-north1 Finland 0.12
northamerica-northeast1 Montreal 0.20
us-west1 Oregon 0.18

Source: AWS 2023 Sustainability Report, Microsoft 2023 Environmental Sustainability Report, Google 2023 Environmental Report.


Recommendation Engine

GreenOps evaluates two strategies per resource and selects the highest-scoring option:

Strategy 1 — ARM upgrade: Switch x86_64 → ARM64 (same vCPU/RAM class). Only recommended if both CO2e and cost decrease. Supported across all three providers.

Strategy 2 — Region shift: Move to the lowest grid-intensity region within the same provider that has pricing data for this instance. Only recommended if CO2e reduction exceeds 15% of baseline.

Scoring:

score = (|co2e_delta| / baseline_co2e) × 0.60
      + (|cost_delta| / baseline_cost) × 0.40

Carbon reduction is weighted at 60%, cost at 40%, both normalised to percentage-of-baseline.

ARM Upgrade Maps

AWS (x86 → ARM64) Azure (x86 → ARM64) GCP (x86 → ARM64)
t3/t3a → t4g Standard_D2s_v3 → Standard_D2ps_v5 n2 → t2a
m5/m5a → m6g Standard_D4s_v3 → Standard_D4ps_v5 n2d → t2a
c5/c5a → c6g Standard_D8s_v3 → Standard_D8ps_v5 e2 → t2a
r5/r5a → r6g Standard_D2s_v4 → Standard_D2ps_v5

Data Sources

Data Source Version
AWS instance TDP Cloud Carbon Footprint hardware coefficients v3
Azure instance TDP Cloud Carbon Footprint Azure coefficients v3
GCP instance TDP Cloud Carbon Footprint GCP coefficients v3
Embodied carbon per server CCF DELL R740 baseline v3
AWS grid carbon intensity Electricity Maps annual averages 2024
Azure grid carbon intensity Electricity Maps annual averages 2024
GCP grid carbon intensity Electricity Maps annual averages 2024
AWS PUE AWS sustainability reports 2023
Azure PUE Microsoft sustainability reports 2023
GCP PUE Google sustainability reports 2023
AWS WUE AWS 2023 Sustainability Report 2023
Azure WUE Microsoft 2023 Environmental Sustainability Report 2023
GCP WUE Google 2023 Environmental Report 2023
AWS pricing AWS public pricing API Q1 2026
Azure pricing Azure public pricing API Q1 2026
GCP pricing GCP public pricing API Q1 2026

Coverage Boundaries and LOW_ASSUMED_DEFAULT

GreenOps only applies emission formulas to instance types explicitly present in factors.json. When a resource is encountered that is not in the ledger, it is classified as LOW_ASSUMED_DEFAULT and excluded from all calculations.

What LOW_ASSUMED_DEFAULT means

LOW_ASSUMED_DEFAULT is not an estimate — it is a deliberate null. The resource appears in the output as ⚠ UNKNOWN in the table formatter and in the skipped section of the markdown PR comment, with the exact unsupportedReason explaining which instance type is missing and from which provider's ledger section.

Why this matters for FinOps auditors

The formula embodied_gco2e = (1,200,000g / 35,040h / 48 vCPUs) × vcpus × 730h is validated against the 71 instance types in the current ledger. Applying it blindly to unsupported instances — particularly memory-optimised families (AWS r6i, Azure Standard_M series, GCP m2 series) with non-standard vCPU-to-memory ratios — would produce numbers that cannot be defended under CSRD audit.

The boundary is intentional. A tool that shows a wrong number is worse than a tool that shows no number.

Heuristic ceiling for auditors

If you need a conservative upper-bound estimate for unsupported instances pending a formal ledger update:

Scope 2 upper bound = W_max × PUE × 730h / 1000 × grid_intensity_gco2e_per_kwh
Scope 3 upper bound = (1,200,000g / 35,040h / 48) × vcpus × 730h

These are the maximum-utilisation values. Actual emissions at typical utilisation (50%) will be lower. Open a PR to factors.json to add the instance type formally with validated coefficients.

Current ledger coverage

Provider Instance types Notable gaps
AWS 40 r6i, c6i, m6i (Intel v3), Graviton 4 (m8g, c8g)
Azure 16 Standard_M series, Standard_L series, Standard_NC (GPU)
GCP 15 n1 series (legacy), m2/m3 memory-optimised, A2 (GPU)

All gaps are tracked as open issues. Coverage PRs are the fastest to merge.


Known Limitations

  • CPU-only power model. Memory power draw is tracked in factors.json (memory_gb) but not yet included in calculations.
  • Scope 2 only for region recommendations. Embodied carbon does not change when shifting regions, so it is correctly excluded from the region-shift scoring.
  • Annual average grid intensity. Real-time marginal emissions are not used. Annual averages are more stable and reproducible, consistent with CCF methodology.
  • WUE at data centre level. Water figures cover direct data centre cooling withdrawal only.
  • Azure and GCP coverage is initial. AWS has 40 instance types; Azure and GCP each have 15–16. Enterprise-scale instance families (M-series, X-series, A2 High Memory) are not yet in the ledger.
  • Provider alias regions. Multi-aliased provider configs may not resolve correctly. Standard single-provider configs are fully supported.

Licence

The methodology, coefficients, and source code are MIT-licensed. Every assertion in engine.test.ts includes a commented math trace derivable from this document and factors.json.