Skip to content

Latest commit

 

History

History
96 lines (53 loc) · 3.63 KB

File metadata and controls

96 lines (53 loc) · 3.63 KB

Mogelijk toekomstige insulinepompen

Dit is een lijst van verschillende insulinepompen, en of ze geschikt zijn voor één van de beschikbare doe-het-zelf closed loop systemen (AndroidAPS, OpenAPS of Loop). Op het einde van deze pagina staat algemene info over welke software-mogelijkheden een pomp moet beschikken om überhaupt "loopbaar" te kunnen zijn.

Kaleido (Homepage)

Loop status: Pump is a Loop candidate, but protocol is unknown at the time. No interest in open source from the vendor.

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:slim X2 (Homepage)

Loop status: Not yet loopable.

While in the past company has decided not to allow their pumps to be controlled by external devices, it seems that last few years have been a game changer. Company decided to upgrade their t:slim X2 pump to be able to be controlled remotely (via t:connect app), which means that avenues are opened that we might be able to look forward to have control of pump via AAPS in the future. New pump firmware is planned to be released soon (this or next year, before their tubeless pump t:sport comes out). There are no details yet, what operations will be possible from t:connect (Bolus definitely, everything else unknown).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:Mobi & t:slim X3 & t:Mobi Tubeless (Homepage)

Loop status: All 3 pumps will be Loop candidates.

Awaiting release of t:mobi in Europe (other two are not yet released anywhere). Development of AAPS t:mobi support has already started and should be available by end of 2025 (see more info on Discord).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Willcare Insulin pump (Homepage)

Loop status: At the moment its not Loop candidate, but we were contacted by their staff and they interested in extending their pump to be loopable (at the moment I think its missing only get/set profile commands).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Comments: Since company is interested in integration with AAPS, they might do implementation themselves.

Pompen die niet meer worden verkocht (fabrikanten zijn gestopt)

Animas Vibe

Animas Ping

Cellnovo

Accu-Chek Insight

Comments: End of support March 2025.

Pompen die niet loopbaar zijn

Medtronic Bluetooth

Comments: Medtronic withdrew.

Accu-Chek Solo

Comments: No community success in communicating with the Solo pump.

Ypsomed Pump

Comments: Ypso added very heavy 3rd party encryption.

Eisen aan pompen die loopbaar zijn

Prerequisite

  • Pomp moet op één of andere manier op afstand bedienbaar zijn. (Bluetooth, radiofrequentie, etc)
  • Communicatie-protocol is gehackt/gedocumenteerd/etc.

Minimal requirement

  • Heeft een mogelijkheid voor het instellen van Tijdelijke Basaalstanden
  • De Pompstatus kan worden uitgelezen
  • Heeft een mogelijkheid voor het annuleren van Tijdelijke Basaalstanden

For oref1(SMB) or Bolusing:

  • Bolus kunnen instellen

Good to have

  • Annuleer Bolus
  • Lees Basaalprofiel uit (is haast een vereiste)
  • Stel Basaalprofiel in (leuk om te hebben)
  • Lees geschiedenis uit

Other (not required but good to have)

  • Vertraagde bolus instellen
  • Vertraagde bolus annuleren
  • Lees geschiedenis uit

Other pumps support

If you have any other pumps you would like to see status on, please contact us on discord.