Sterowniki do pomp (prawdopodobne) w przyszłości

Poniżej znajduje się lista niektórych pomp, które mogą działać w pętli, status ich wsparcia w dowolnym systemie pętlowym, oraz status dla systemu AAPS. Na końcu jest trochę informacji, jakie są wymagania, aby pompa nadawała się do pracy w pętli.

Pumps that are Loopable

Kaleido (Homepage)

Loop status: Pump is a Loop candidate, but protocol is unknown at the time. No interest in open source from the vendor.

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:slim X2 (Homepage)

Loop status: Not yet loopable.

While in the past company has decided not to allow their pumps to be controlled by external devices, it seems that last few years have been a game changer. Company decided to upgrade their t:slim X2 pump to be able to be controlled remotely (via t:connect app), which means that avenues are opened that we might be able to look forward to have control of pump via AAPS in the future. New pump firmware is planned to be released soon (this or next year, before their tubeless pump t:sport comes out). There are no details yet, what operations will be possible from t:connect (Bolus definitely, everything else unknown).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Tandem: t:Mobi & t:slim X3 & t:Mobi Tubeless (Homepage)

Loop status: All 3 pumps will be Loop candidates.

Awaiting release of t:mobi in Europe (other two are not yet released anywhere). Development of AAPS t:mobi support has already started and should be available by end of 2025 (see more info on Discord).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Willcare Insulin pump (Homepage)

Loop status: At the moment its not Loop candidate, but we were contacted by their staff and they interested in extending their pump to be loopable (at the moment I think its missing only get/set profile commands).

Hardware requirement for AAPS: None. It seems to be BT enabled.

Comments: Since company is interested in integration with AAPS, they might do implementation themselves.

Pumps no longer sold (companies no longer operating)

Animas Vibe

Animas Ping

Cellnovo

Accu-Chek Insight

Comments: End of support March 2025.

Pumps that aren't Loopable

Medtronic Bluetooth

Comments: Medtronic withdrew.

Accu-Chek Solo

Comments: No community success in communicating with the Solo pump.

Ypsomed Pump

Comments: Ypso added very heavy 3rd party encryption.

Requirements for pumps being loopable

Prerequisite

  • Pump has to support some kind of remote control. (BT, Radio frequency, etc)
  • Protocol is hacked/documented/etc.

Minimal requirement

  • Set Temporary Basal Rate
  • Get Status
  • Cancel Temporary Basal Rate

For oref1(SMB) or Bolusing:

  • Set Bolus

Good to have

  • Cancel Bolus
  • Get Basal Profile (almost requirement)
  • Set Basal Profile (nice to have)
  • Read History

Other (not required but good to have)

  • Set Extended Bolus
  • Cancel Extended Bolus
  • Read History
  • Read TDD

Other pumps support

If you have any other pumps you would like to see status on, please contact us on discord.