Expand Up @@ -51,6 +51,16 @@ The power system has been revised in May 2016, leading to the design of a new pu
In 2017, a second pump was added. The pumps are driven by having stacked PCBs from 2016. Furthermore, a shield made from veroboard was made. It works as a normal shield instead of an "inverted shield". This way if the Prismino dies, any other can be used.
Also, the amount of liquid to be poured is now measured using a scale instead of a timer (ie no measurement). This required the hand to be redesigned and the design can be found on the Fusion360 account of Robopoly.

## CHANGELOG
### 2025 Maintenance and repair
In may 2025, repair and maintenance was done by Tibor Truong.
The design of both hands was modified in order to adapt to various sizes of glasses and improve reliability. The loadcell was removed from it's plattform underneath the cup holder and was integrated directly into the cup holder (holder itself measures the weight). The hand on the "pouring" side was also redesigned. The hoses can now be installed and removed way faster thanks to zipties.
The switch that sensed the closing of the hands was replaced by a reed sensor. This ensures that contact is closed even when the arms don't touch very well (due to mechanical play).
The existing two pumps were thoroughly cleaned with a 1% NaOH solution to get rid of the mold and other gunk that has been building up for years.
During repair, the loadcell amplifier board was damaged, it got replaced by a more recent model sold by Robopoly.

Note for users: Please always rince the hoses at least with warm water (or better with a desinfecting solution) and dry them completely before putting away the robot for storage. Leaving liquids in the pumps and hoses leads to mold formation and it's very work intensive to get rid of it again. Not even mentioning that it's disgusting and not foodsafe.