44 changes: 44 additions & 0 deletions docs/deployments/tomowise/equipment/detector.md
Original file line number Diff line number Diff line change
Expand Up @@ -4,6 +4,46 @@

TomoWISE has a single detector system on a gantry that travels the experiment hutch on 7 m floor rails, from the microtomography station at 45 m to the hutch wall at 52 m. It serves both endstations, so it is modelled once, in the detection stage of the [descriptor](../inventory.md).

## The model in one picture

What physically holds what, gantry down to the optics (containment, `Asset.parent_id`):

```
TomoWISE (Unit, Asset)
└── DetectorGantry (Component, Family Table; Xd/Yd/Zd on 7 m rails; the shared propagation rail)
├── MicLFOV (Component, Family Housing; model optique_peter_micrx080)
│ ├── Turret (Device, LinearStage; objective changer)
│ ├── Objective_1x (Device, Objective)
│ ├── Objective_2x (Device, Objective)
│ ├── ObjectiveSelector (Device, PseudoAxis)
│ └── Scintillator (Device, Scintillator)
├── MicHR (Component, Family Housing; model optique_peter_micrx080)
│ ├── Turret (Device, LinearStage; objective changer)
│ ├── Objective_4x (Device, Objective)
│ ├── Objective_10x (Device, Objective)
│ ├── Objective_20x (Device, Objective)
│ ├── ObjectiveSelector (Device, PseudoAxis)
│ └── Scintillator (Device, Scintillator)
└── CameraI / CameraII / CameraIII / CameraIV (Device, Camera; shared pool, paired per run)
```

Each microscope is the cross-facility `Microscope` Assembly (the same blueprint 2-BM uses), composing the reusable `Optics` sub-assembly plus the leaf slots. Unlike 2-BM, no Fixture is registered yet (TomoWISE is design-phase: no scenario binds Assets to slots), so the slot map below is the **planned** composition, not a materialized Fixture:

```
Planned composition (no Fixture registered yet) -- per microscope
materializes Assembly = Microscope (presents_as the Detector Role)
├── sub-assembly optics -> Assembly = Optics
│ ├── turret (Exactly1) -> Turret
│ ├── objectives (OneOrMore) -> Objective_1x, Objective_2x (MicLFOV)
│ │ Objective_4x, Objective_10x, Objective_20x (MicHR)
│ ├── objective_selector (Exactly1) -> ObjectiveSelector
│ └── propagation_distance (ZeroOrOne) -> (empty; the shared DetectorGantry rail provides it)
├── leaf slot scintillator (Exactly1) -> Scintillator
└── leaf slot camera (ZeroOrOne) -> (empty; drawn from the shared camera pool per run)
```

Two axes, orthogonal: **containment** (`Asset.parent_id`, the tree above) is what holds what; **composition** (Assembly to Fixture, the slot map) is what presents for binding. The `camera` and `propagation_distance` slots are `ZeroOrOne` and left empty here because TomoWISE shares its four cameras and one gantry rail across both microscopes (the catalog assembly was generalized to allow this); the `Housing` binds `optique_peter_micrx080` as the design-target candidate (DET-2).

## Gantry

| Device | Family | Design spec (TDR) |
Expand Down Expand Up @@ -32,4 +72,8 @@ Four cameras span the throughput-versus-speed-versus-resolution trade, all share
| `CameraIII` | `Camera` | ~4 Mpix, > 2,000 fps; streaming |
| `CameraIV` | `Camera` | 150 Mpix, 54 x 40 mm sensor, 3.76 um pixel; matches the large-sensor device procured for DanMAX |

## Families

All reused, none new: `Table` (the gantry), `Housing` (each microscope chassis, binding `optique_peter_micrx080`), `LinearStage` (the objective-changer turret), `Objective` (per-lens identity), `PseudoAxis` (the objective selector), `Scintillator`, and `Camera`. The composition reuses the 2-BM `Microscope` / `Optics` Assembly blueprints unchanged; only the `camera` and `propagation_distance` slot cardinalities were generalized to `ZeroOrOne`.

The camera models, the bound microscope-optics model confirmation (DET-2), and the trigger path are the main detector-side [open questions](../questions.md). See [Inventory](../inventory.md) for the Asset tree.
33 changes: 33 additions & 0 deletions docs/deployments/tomowise/equipment/sample.md
Original file line number Diff line number Diff line change
Expand Up @@ -4,6 +4,39 @@

The sample stage is two experiment stations in the experiment hutch, sharing one [Detector](detector.md) gantry: a microtomography station (~45 m) and a nanotomography station (~49 m). They are modelled as two sample-stage groups in the [descriptor](../inventory.md), each presenting the specimen to the beam in a different way. Models named "(target)" are the TDR design selections, carried unbound until procurement confirms them.

Unlike the [Detector](detector.md), the sample stage is **not modelled as a catalog Assembly** here: it is a device group, not a composed `Microscope`-style blueprint. (2-BM models its sample positioning as a `SampleTower` Assembly + Fixture; TomoWISE could earn the same once the manipulator firms and a scenario registers it.) So these pages carry the containment trees but no Assembly-to-Fixture composition diagram.

## The model in one picture

The kinematic stacks, base to sample (containment, `Asset.parent_id`). The precise sub-order firms with the mechanical design (TDR manipulator tables 9.1 / 9.5); the trees below are the design-layout intent.

Microtomography (~45 m), mirroring the standard table -> tilt -> rotary -> sample-top order:

```
TomoWISE (Unit, Asset)
└── SampleTable (Component, Family Table; base, fixed at 45 m, Xt/Yt/beta)
├── LaminographyTilt (Device, TiltStage; tilts the rotation axis, alpha)
│ └── Rotary (Device, RotaryStage; wy, master rotation + trigger clock)
│ ├── SamplePositioning (Device, LinearStage; Xs/Zs, co-rotates)
│ └── SlipRing (Device, SlipRing; continuous-rotation feedthrough)
├── SampleSlit (Device, Slit; sample-side, beam-defining)
└── FastShutter (Device, Shutter; sample-side)
```

Nanotomography (~49 m), the granite carrying the KB optics and the coarse-to-fine manipulator:

```
TomoWISE (Unit, Asset)
└── NanoGranite (Component, Family Table; granite support, ~49 m)
├── KB (Device, Mirror; KB focusing pair)
└── NanoCoarseZ (Device, LinearStage; Zt, long-travel into the KB focus)
└── NanoCoarseY (Device, LinearStage; Yt, sample height)
└── NanoCoarseX (Device, LinearStage; Xt, centre-of-rotation)
└── NanoTilt (Device, TiltStage; Tilt X, axis-to-beam)
└── NanoRotary (Device, RotaryStage; Rot y, continuous rotation)
└── NanoSamplePositioning (Device, LinearStage; Xs/Zs, fine centring)
```

## Microtomography endstation (~45 m)

The workhorse station: a fixed sample table about 45 m from the source carrying the rotation and positioning stack. The `Rotary` stage is also the trigger master clock (see [Controls](controls.md)).
Expand Down